Single-core flexible PV cable with a tinned-copper Class 5 conductor and electron-beam cross-linked XLPO insulation — for module, string, combiner box and inverter wiring on rooftops, solar farms and off-grid systems.

Everything a solar engineer checks first — before diving into the full datasheet below.
The H1Z2Z2-K 6mm² is a single-core flexible photovoltaic cable specified to EN 50618:2014 and IEC 62930, with construction aligned to the TÜV 2PfG 1169 (PV1-F) requirements. It is the cable that runs between modules, along the string, into the DC combiner box and on to the inverter.
The conductor is Class 5 flexible stranded tinned copper per EN/IEC 60228. Tinning keeps the strand surface stable in humid, coastal and polluted conditions, while the fine stranding makes the cable easy to route around module frames and into junction boxes. The 6mm² size carries 67 A on a surface and 70 A in free air at 60°C ambient, per EN 50618 Table A3, and its maximum DC resistance is 3.39 Ω/km at 20°C.
Insulation and sheath are both electron-beam cross-linked XLPO, halogen-free and low smoke. The cross-linked structure is what allows a 90°C continuous conductor temperature (120°C for up to 20 000 h), resists UV, ozone and hydrolysis, and supports the 25-year minimum design life that EN 50618 requires.
Rated 1.5/1.5 kV DC with a maximum permissible operating voltage of 1.8/1.8 kV, the cable is intended for 1500V DC string architectures — the standard for modern utility-scale and large commercial plants where higher string voltage reduces cable runs and losses.
More about the manufacturer: About SORIVO →
Specified to the European photovoltaic cable standard and its IEC equivalent, with construction aligned to TÜV 2PfG 1169 (PV1-F).
Class 5 flexible stranded tinned copper per EN/IEC 60228 — flexible routing plus a corrosion-resistant strand surface for long outdoor service.
Insulation and sheath are cross-linked by electron beam, giving a thermally and mechanically stable compound rather than a thermoplastic jacket.
1.5/1.5 kV DC with 1.8/1.8 kV maximum permissible operating voltage — matched to modern 1500V DC string architectures.
EN/IEC 60754-1 and 60754-2 for halogen acid gas, EN/IEC 61034-1/-2 for smoke density with light transmittance above 70% — relevant for rooftops and enclosed spaces.
90°C continuous conductor temperature for the full design life, 120°C for up to 20 000 h, and 250°C for a maximum of 5 s under short circuit.
Weathering resistance per EN 50618 Annex E, ozone resistance per EN 50396, and AD7 immersion water resistance — built for permanent outdoor exposure.
The same H1Z2Z2-K construction is available from 1.5 mm² to 35 mm², so a project can standardise on one cable family from string to inverter.
From a rooftop string to a utility-scale array — one construction, sized per project.
String and array DC cabling between module rows, combiner boxes and central inverters.
Module-to-module and string runs on large rooftops, where tight bends and long service life both matter.
Panel-to-inverter DC wiring in home systems, including hybrid and retrofit installations.
String inputs and DC distribution inside combiner boxes, where bend radius and sheath toughness matter.
DC input side of string and central inverters, sized for continuous current and voltage drop.
Building-integrated PV, where halogen-free, low-smoke performance is part of the specification.
Floating plants and agricultural or fishery PV, where UV, hydrolysis and humidity resistance are decisive.
Remote power, solar-plus-storage and hybrid systems where the DC cabling must last without maintenance.
The complete parameter set — the same data our engineers quote from.
| Cross-section mm² | Conductor dia. max. mm | Overall diameter min. – max. mm | Min. bending radius fixed, mm | Weight approx. kg/km | Max. DC resistance at 20°C, Ω/km | Current in free air at 60°C, A | Current on a surface at 60°C, A |
|---|---|---|---|---|---|---|---|
| 1.5 | 1.6 | 4.4 – 5.0 | 15 | 35 | 13.7 | 30 | 29 |
| 2.5 | 1.9 | 4.8 – 5.4 | 17 | 46 | 8.21 | 41 | 39 |
| 4 | 2.4 | 5.3 – 5.9 | 18 | 61 | 5.09 | 55 | 52 |
| 6 | 2.9 | 5.8 – 6.4 | 20 | 80 | 3.39 | 70 | 67 |
| 10 | 4.0 | 7.0 – 7.6 | 23 | 122 | 1.95 | 98 | 93 |
| 16 | 5.6 | 9.0 – 9.8 | 30 | 200 | 1.24 | 132 | 125 |
| 25 | 6.4 | 10.3 – 11.2 | 34 | 290 | 0.795 | 176 | 167 |
| 35 | 7.5 | 11.7 – 12.5 | 50 | 400 | 0.565 | 218 | 207 |
The 6 mm² row is highlighted — it is the size this page covers. Current ratings are single cable at 60°C ambient per EN 50618 Table A3; for higher ambient temperatures apply the EN 50618 Table A4 factors: 70°C × 0.92, 80°C × 0.84, 90°C × 0.75. For grouped or touching cables refer to the two-loaded-cables values and HD 60364-5-52. Dimensions are nominal and subject to manufacturing tolerance.
| General Information | |
| Product Name | H1Z2Z2-K 6mm² Solar PV Cable (single core) |
| Primary Standard | EN 50618:2014 — cables for photovoltaic systems |
| Further Standards | IEC 62930; TÜV 2PfG 1169 (PV1-F); EN / IEC 60228 |
| Rated Voltage AC | U0/U 1.0/1.0 kV AC, maximum permissible operating voltage 1.2/1.2 kV |
| Rated Voltage DC | U0/U 1.5/1.5 kV DC, maximum permissible operating voltage 1.8/1.8 kV — intended for 1500V DC strings |
| Test Voltage | 6.5 kV AC or 15 kV DC (alternative tests), 5 minutes |
| Cable Structure | Single core, 1 × 6 mm²; the same construction is available from 1.5 mm² to 35 mm² |
| Core Identification | Black (standard) / Red — polarity marking of the PV string |
| Conductor | |
| Conductor Material | Electrolytic annealed tinned copper — corrosion resistant strand surface |
| Conductor Type | Class 5 flexible stranded conductor, per EN / IEC 60228 |
| Max. DC Resistance | 6 mm²: 3.39 Ω/km at 20°C (other sizes in Table 1) |
| Conductor Diameter | 6 mm²: 2.9 mm maximum |
| Insulation & Sheath | |
| Insulation Material | XLPO (cross-linked polyolefin), electron-beam cross-linked, halogen-free |
| Sheath / Jacket | XLPO (cross-linked polyolefin), LSZH, UV and ozone resistant |
| Insulation / Sheath Thickness | 6 mm²: 0.7 mm insulation, 0.8 mm sheath (nominal, per the applicable EN 50618 construction) |
| Halogen-Free | EN / IEC 60754-1; corrosive gases per EN / IEC 60754-2 |
| Smoke Density | EN / IEC 61034-1 and EN / IEC 61034-2 — light transmittance > 70% |
| Sheath Colours | Black (standard) / Red; other colours on request |
| Sheath Marking | SORIVO H1Z2Z2-K 1 × <size> mm² 1.0/1.0 kV AC 1.5 kV DC EN 50618 IEC 62930 <year> — or per customer requirement |
| Electrical Ratings | |
| Current Carrying Capacity | 6 mm²: 70 A in free air / 67 A on a surface at 60°C ambient; two cables touching on a surface: 57 A (EN 50618 Table A3) |
| Ambient Derating | Per EN 50618 Table A4: 70°C × 0.92, 80°C × 0.84, 90°C × 0.75 |
| Insulation Resistance | ≥ 800 MΩ·km at 20°C — SORIVO in-house routine test value |
| Voltage Drop (6 mm²) | ≈ 6.78 V/A/km for the complete circuit loop at 20°C conductor temperature |
| Temperature & Environmental | |
| Ambient Temperature | −40°C to +90°C, fixed installation; −25°C to +60°C during handling and installation |
| Max. Conductor Temperature | +90°C continuous (design life per EN 50618); +120°C for up to 20 000 h |
| Max. Short-Circuit Temperature | +250°C, maximum 5 seconds |
| Cold Performance | Cold bending, elongation and impact at −40°C per EN 60811-504 / -505 / -506 |
| UV Resistance | EN 50618 Annex E (720 h / 360 cycles, EN 50289-4-17 method A) |
| Ozone Resistance | Per EN 50396, test type B |
| Water Resistance | AD7 immersion per EN 50618; AD8 submersion class agreed per order and supported by the test record for the construction supplied |
| Flame Performance | EN / IEC 60332-1-2, single cable vertical flame propagation |
| Minimum Bending Radius | 3 × overall diameter for cables up to 12 mm OD; 4 × overall diameter above 12 mm OD, per EN 50565-1 (per-size values in Table 1) |
| Design Life | Minimum 25 years per EN 50618; typically 30 years at 90°C conductor temperature on the Arrhenius basis |
| Reaction to Fire (CPR) | Classified under EN 50575 — the declared class for the selected construction is stated on the Declaration of Performance |
| Packaging & Logistics | |
| Packaging | Wooden drum / coil / reel / custom packaging per request |
| Standard Length | 100 m / 200 m / 500 m per roll, customizable |
| MOQ | 3,000 meters for this size; the MOQ is set per cross-section and construction, so it differs across the size range — sample orders are negotiable in every case |
| Lead Time | 7–15 working days; stocked sizes may be available in 3–5 days |
Final cable selection should be based on string current, system voltage, run length, short-circuit conditions, installation method and applicable local requirements. Our engineers confirm the exact construction and certification scope with your project data.
The European standard for cables in photovoltaic systems and its IEC equivalent — the design basis of this cable. Certificate of conformity available on request.
Request certificate copy →The TÜV specification for photovoltaic cables, referenced alongside EN 50618 — with conductor and test data verified for every production batch.
Request test report →EN/IEC 60754-1 and 60754-2, EN/IEC 61034-1/-2 and EN/IEC 60332-1-2 — the fire performance set required for rooftops and enclosed installations.
Request test report →
Every drum of solar cable is produced under controlled processes and released against the applicable EN 50618 requirements.
Tell us cross-section, colour, quantity and destination market.
We confirm construction, certification scope and quotation within one working day.
Sample for qualification — stocked sizes within a few working days.
7–15 working days lead time with batch test documentation.
Wooden drum packing, shipping documents and after-sales support.