UL 83 · UL 1063 (MTW) · 600V · ASTM B787

THHN 8 AWG Stranded Copper Building Wire

19-strand bare annealed copper building wire with PVC insulation and a nylon jacket — for branch circuits, feeders and control wiring pulled through conduit and raceway in commercial and industrial buildings.

600V
Rated Voltage
+90°C dry
+75°C wet (THHN)
19-strand
Bare Copper
8 AWG
8.37 mm² nominal
↓ Download Datasheet (PDF)
UL 83 / UL 1063 (MTW) VW-1 flame rated Sample orders available OEM colours & packing
THHN BUILDING WIRE · 8 AWG THHN 8 AWG stranded copper building wire on spools — SORIVO
UL 83THHN / THWN-2 wire
UL 1063MTW, stranded only
ASTM B78719-wire combination unilay
NEC 310.1640 / 50 / 55 A at 60 / 75 / 90°C
600V · +90°Cdry; +75°C wet
Key Specifications

The essentials, at a glance

Everything an electrical contractor or inspector checks first — before diving into the full datasheet below.

600V
Rated voltage, UL 83
19 strands
Combination unilay, ASTM B787
PVC + Nylon
Insulation + jacket
+90°C dry
+75°C wet (THHN) / +90°C wet (THWN-2)
40 / 50 / 55 A
NEC 310.16, 60 / 75 / 90°C columns
62 lb/1000 ft
Approx. weight (≈94 kg/km)
Product Overview

The 600V workhorse behind a 50 A circuit

The THHN 8 AWG Stranded Copper Building Wire is a single-conductor, 600V thermoplastic-insulated building wire manufactured to UL 83. The same construction is printed and listed as THWN-2, so one spool covers dry and wet locations in conduit, raceway, cable tray and machine-tool wiring. The nominal cross-section is 8.37 mm².

The conductor is 19 strands of soft annealed bare copper, stranded combination unilay to ASTM B787 — a compact 3.75 mm stranded conductor (19 × 0.75 mm) that pulls easily through bends and terminates reliably under a lug or wire nut. PVC insulation of 0.76 mm (0.030 in) is covered by a 0.13 mm (0.005 in) nylon jacket; the finished stranded wire measures 5.6 mm (0.230 in) overall and weighs about 62 lb/1000 ft (≈94 kg/km).

Ampacity follows NEC Table 310.16, which lists 40 A at 60°C, 50 A at 75°C and 55 A at 90°C for not more than three current-carrying conductors in a raceway or cable at 30°C ambient. The 90°C figure is not a free upgrade: under NEC 110.14(C) the conductor ampacity may not exceed the lowest temperature rating of any connected termination, conductor or device, and the practical value is 50 A on 75°C terminations — note that NEC 240.4(D) does not reach 8 AWG, because its small-conductor protection caps stop at 10 AWG. The 90°C column is used only for ampacity adjustment and correction.

Two resistance values matter and they are not interchangeable. The 20°C calculated value is 2.06 Ω/km — ideal copper resistivity over the nominal cross-section, useful for comparing constructions. The value to use for voltage drop and code work is the NEC Chapter 9 Table 8 figure for stranded uncoated copper at 75°C: 0.778 Ω/1000 ft, about 2.55 Ω/km.

THHN is rated +90°C in dry locations and +75°C in wet locations, while the THWN-2 listing covers +90°C dry and wet and +75°C where the wire is exposed to oil. The construction is not listed for direct burial, so route it in a raceway or select a direct-burial-listed cable. An 8 AWG conductor is the usual choice for 40–50 A feeders, sub-panels, ranges and HVAC equipment, where the 8.37 mm² cross-section keeps voltage drop manageable on medium-length runs.

More about the manufacturer: About SORIVO →

Key Features

Eight features that matter on a 8 AWG pull

UL 83 / UL 1063 (MTW)

Manufactured to UL 83 for thermoplastic-insulated wire and listed as MTW to UL 1063 for stranded constructions used in machine-tool and control panel wiring.

19-Strand Bare Copper

Soft annealed bare copper, 19 strands stranded combination unilay to ASTM B787 — a 3.75 mm conductor with the flexibility solid wire cannot match.

PVC Insulation + Nylon Jacket

0.76 mm (0.030 in) PVC insulation under a 0.13 mm (0.005 in) nylon jacket — 600V dielectric strength with the abrasion and cut-through resistance a pull through steel conduit demands.

600V, +90°C Dry

Rated 600V for all applications: +90°C in dry locations, +75°C wet as THHN, and +90°C in both dry and wet locations as THWN-2.

VW-1 Flame Rated

Vertical wire flame test to UL 1581. VW-1 applies to all sizes of this construction, including 8 AWG.

NEC 310.16 Ampacity, Correctly Applied

40 A at 60°C, 50 A at 75°C and 55 A at 90°C per NEC 310.16, published together with the NEC 110.14(C) termination limit and the 50 A practical circuit ampacity — so the number on this page matches the number in the panel.

Two Labelled DC Resistances

2.06 Ω/km at 20°C, stated as a calculated value, and the NEC Chapter 9 Table 8 value at 75°C of 0.778 Ω/1000 ft (≈2.55 Ω/km) — never blended into one number.

Eleven Standard Colours

Black, white, red, blue, green, yellow, gray, brown, orange, violet and pink, supplied on spool, coil or reel with OEM colour and packing options.

Applications

Where 8 AWG THHN / THWN-2 goes

From a lighting branch circuit to a machine-tool panel — one construction, sized per circuit.

01

Branch Circuits

50 A feeders and sub-panel supplies for ranges, HVAC equipment and light commercial distribution.

02

Panelboards & Feeders

Panelboard and load-centre terminations and short feeders inside electrical rooms, where a compact 5.6 mm wire keeps conduit fill workable.

03

Lighting Circuits

Lighting branch circuits and switch legs in office, retail and warehouse space, pulled in EMT, IMC or PVC conduit.

04

Control & Signal Wiring

Control, relay and signal circuits inside enclosures and wireways, where the MTW listing and flexible stranding simplify routing.

05

HVAC & Mechanical Equipment

Disconnects, contactors and motors on rooftop units and air handlers, terminated in equipment rated for the application.

06

Machine Tool & Panel Wiring

Machine-tool and industrial control panel wiring under the UL 1063 (MTW) listing, which applies to stranded constructions.

07

Industrial Plants & Warehouses

Long raceway runs where lubricated pulls and a consistent 5.6 mm outside diameter keep installation time predictable.

08

Renovation & Retrofit Pulls

Rewires and tenant fit-outs where existing conduit is tight and a 19-strand conductor bends and pulls more easily than solid wire.

Technical Specifications

Full specification sheet

The complete parameter set — the same data our engineers quote from.

Table 1 Dimensions, weight, resistance and ampacity by size

AWG
size
Strands
count
Conductor dia.
stranded, mm
PVC insulation
mm (in)
Nylon jacket
mm (in)
Overall dia.
mm (in)
Weight
lb/1000 ft (kg/km)
DC resistance
20°C calc., Ω/km
DC resistance
75°C, Table 8, Ω/1000 ft
Ampacity
60°C, A
Ampacity
75°C, A
Ampacity
90°C, A
12192.350.38 (0.015)0.10 (0.004)3.5 (0.140)23 (36)5.211.98202530
10193.000.51 (0.020)0.10 (0.004)4.3 (0.170)38 (57)3.281.24303540
8193.750.76 (0.030)0.13 (0.005)5.6 (0.230)62 (94)2.060.778405055

The highlighted 8 AWG row is the size this page covers. Ampacity values are NEC Table 310.16 for not more than three current-carrying conductors in a raceway or cable at 30°C ambient. The 90°C column is permitted for ampacity adjustment and correction only, per NEC 110.14(C) — it does not raise the ampacity of a circuit whose terminations are rated 60°C or 75°C. The 20°C resistance is a calculated value derived from ideal copper resistivity over the nominal cross-section and is not the NEC Chapter 9 Table 8 figure, which is listed at 75°C for stranded uncoated copper. Dimensions are nominal and subject to manufacturing tolerance.

Table 2 Construction and performance parameters

General Information
Product NameTHHN 8 AWG Stranded Copper Building Wire (single conductor, stranded)
Product TypeTHHN / THWN-2 thermoplastic-insulated building wire
AWG Size8 AWG — 8.37 mm² nominal cross-section
Primary StandardUL 83 — thermoplastic-insulated wires and cables
Further StandardsUL 1063 (MTW); ASTM B787 and ASTM B3; CSA C22.2 No. 75
CertificationUL 83 / UL 1063 (MTW) / CSA C22.2 No. 75 (c-UL T90 Nylon, TWN75) / RoHS — scope confirmed against the certificate for the selected construction
Rated Voltage600V
Conductor
Conductor MaterialSoft annealed bare copper
Stranding19 strands, combination unilay per ASTM B787
Conductor Diameter (Stranded)3.75 mm (19 × 0.75 mm)
Max. DC Resistance @20°C (calculated)2.06 Ω/km — calculated from ideal copper resistivity over the 8.37 mm² nominal cross-section
Max. DC Resistance @75°C (NEC Ch.9 Table 8)0.778 Ω/1000 ft ≈ 2.55 Ω/km for stranded uncoated copper
Insulation & Jacket
Insulation MaterialPVC (polyvinyl chloride)
Insulation Thickness0.76 mm (0.030 in)
Jacket MaterialNylon (polyamide)
Jacket Thickness0.13 mm (0.005 in)
Overall Diameter (Stranded)5.6 mm (0.230 in)
Weight≈ 62 lb/1000 ft (≈ 94 kg/km)
Available ColoursBlack, White, Red, Blue, Green, Yellow, Gray, Brown, Orange, Violet, Pink
Colour RulesGreen is used for equipment grounding and white or gray for the grounded conductor, per NEC 250.119 and 200.6
Electrical Ratings
Ampacity (NEC 310.16)40 A at 60°C / 50 A at 75°C / 55 A at 90°C — not more than three current-carrying conductors in a raceway or cable, 30°C ambient
Practical Circuit Ampacity50 A — limited by the NEC 110.14(C) termination temperature rule; the NEC 240.4(D) small-conductor protection caps stop at 10 AWG and do not extend to 8 AWG
Use of the 90°C ColumnPermitted for ampacity adjustment and correction only, per NEC 110.14(C) — the corrected ampacity may not exceed the column matching the terminations
Referenced TablesNEC Table 310.16 (formerly 310.15(B)(16)); see also NEC 310.15 and 110.14(C) — NEC 240.4(D) is cited here only to record that its small-conductor caps end at 10 AWG
Temperature & Environmental
Temperature Rating (THHN)+90°C dry / +75°C wet
Temperature Rating (THWN-2)+90°C dry and wet; +75°C where the wire is exposed to oil
FlammabilityVW-1 vertical wire flame test per UL 1581
Oil ResistanceGasoline and oil resistant II, as covered by the UL 83 / UL 1063 listing of this construction
Moisture ResistanceWet-location rated through the THWN / THWN-2 designations of UL 83
Abrasion ResistanceNylon jacket provides high abrasion and cut-through resistance during pulling
Sunlight ResistanceNot claimed for this construction — for outdoor exposure run the wire in a raceway or select a sunlight-resistant listed cable
Direct BurialNot listed for direct burial — use a raceway, or select a direct-burial-listed cable (UF / USE)
Tray RatingsFT4 / IEEE 1202 tray ratings are not claimed for 8 AWG
Packaging & Logistics
PackagingSpool / Coil / Reel
Standard Lengths100 ft / 500 ft / 1000 ft per spool
MOQ1 spool (sample order available)
Lead Time5–15 working days (stock: 3–5 days)

Final selection should be based on circuit loading, overcurrent protection, ambient temperature, conduit fill, voltage drop and the temperature rating of the terminations actually used. Our engineers confirm the construction, colour and certification scope against your project data.

Certificates & Standards

Verify before you buy — we make it easy

UL 83 / UL 1063 (MTW)

UL 83 is the standard for thermoplastic-insulated wire; UL 1063 is the machine-tool wire listing carried by the same stranded construction. Certificate of conformity available on request.

Request certificate copy →

CSA C22.2 No. 75

The Canadian standard behind the c-UL T90 Nylon and TWN75 designations, carried on the same 600V wire for projects that specify CSA alongside UL.

Request test report →

VW-1 Flame & RoHS

VW-1 vertical flame rating to UL 1581 and RoHS compliance, both applying to 8 AWG. FT4 / IEEE 1202 tray ratings are not claimed for this size.

Request test report →
Transparency note: certification status and exact scope should always be confirmed against the certificate for the selected wire construction. We provide the certificate and test reports with every quotation — no blank promises.
SORIVO industrial cable factory workshop — production line overview
Quality & Factory

Made in a real cable factory, tested before it ships

Every spool of THHN / THWN-2 building wire is produced under controlled processes and released against the applicable UL 83 requirements.

  • 1Incoming material control — bare copper wire and PVC and nylon compounds are checked before production starts.
  • 2In-line process monitoring — strand count, conductor diameter, insulation concentricity and jacket thickness are tracked during extrusion.
  • 3Routine electrical tests — on-line spark test plus finished-wire voltage, insulation-resistance and conductor-resistance tests: 2.06 Ω/km is checked against the 20°C calculated limit.
  • 4Batch documentation — conductor resistance, dimensions, colour and test records are retained for every production batch.
19+
countries served
60+
building & industrial projects
100%
routine test before shipment
How to Order

From inquiry to loaded spool in 5 steps

Send Inquiry

Tell us the size (8 AWG), colour, quantity and destination market.

Confirm Construction

We confirm stranding, insulation and jacket build, certification scope and quotation within one working day.

Sample Evaluation

Sample for qualification — stock sizes usually ship from existing spools within a few working days.

Bulk Production

5–15 working days lead time, with batch test documentation.

Delivery & Support

Spool, coil or reel packing, shipping documents and after-sales support.

FAQ

Questions buyers ask before ordering

They are temperature and location ratings carried by the same wire. THHN is rated +90°C in dry locations; THWN is +75°C in wet locations; THWN-2 is +90°C in both dry and wet locations, and +75°C where the wire is exposed to oil. Sorivo supplies the construction printed as THHN / THWN-2, so one spool covers dry and wet raceway work at 600V.
NEC Table 310.16 gives 40 A at 60°C, 50 A at 75°C and 55 A at 90°C for not more than three current-carrying conductors in a raceway or cable at 30°C ambient. What the circuit can actually carry is lower: NEC 110.14(C) caps the conductor ampacity at the lowest temperature rating of the connected terminations and devices, and NEC 240.4(D) adds no further cap at this size because its small-conductor limits stop at 10 AWG. In practice this is a 50 A circuit, and the 90°C column is used only for ampacity adjustment and correction.
Because the insulation rating is not the circuit rating. NEC 110.14(C) requires the temperature rating used for ampacity to be coordinated with — and not higher than — the lowest temperature rating of any connected termination, conductor or device. Most breakers and devices rated 100 A or less are marked for 60°C or 75°C terminations. The 90°C column still matters: it may be used for ampacity adjustment and correction, but the corrected value may not exceed the column that matches the terminations.
Two figures, and they are not interchangeable. The 20°C calculated value is 2.06 Ω/km, derived from ideal copper resistivity over the 8.37 mm² nominal cross-section — useful for comparing constructions. The value to use for voltage drop and code work is the NEC Chapter 9 Table 8 figure for stranded uncoated copper at 75°C: 0.778 Ω/1000 ft, about 2.55 Ω/km.
Outdoors, yes — provided the wire is installed in a raceway or another approved enclosure, because the THWN-2 rating covers wet locations at +90°C. Direct burial is not supported: THHN / THWN-2 is a wet-location conductor, not a direct-burial cable, and it is not listed for that use. For a direct-burial run choose a UF or USE listed cable, or provide a raceway.
It depends on the circuit. The NEC 310.16 columns at 60 / 75 / 90°C are 20 / 25 / 30 A for 12 AWG, 30 / 35 / 40 A for 10 AWG and 40 / 50 / 55 A for 8 AWG, and the practical circuit ampacities on 60°C and 75°C terminations are 20 A, 30 A and 50 A respectively. An 8 AWG conductor is the usual choice for 40–50 A feeders, sub-panels, ranges and HVAC equipment, where the 8.37 mm² cross-section keeps voltage drop manageable on medium-length runs. For long runs the deciding factor is usually voltage drop rather than ampacity. Send us the load, the run length and the terminations and we will confirm the size.
Yes. Certificate and test documentation is provided with the quotation and with the shipment, and the exact scope is always confirmed against the certificate for the selected construction before the order is placed. Sample orders are available, and stock sizes usually ship from existing spools. We would rather show you the document than describe it — request it through the form below.
THHN / THWN-2 is the UL 83 conductor for raceway wiring in North American projects. If your project is instead specified to the European BS 6004 / IEC 60227 single-core PVC range — 6491X H07V-R — we supply that construction as well: PVC Single Core Cable 6491X H07V-R. The two families serve different markets; tell us the destination and we will quote the one your inspector expects.

Need a sample of 8 AWG THHN for your project?

Tell us the size, colour and quantity — we reply within one working day.

Get a Free Quote

Send your building wire requirement

The more detail you give, the faster and more accurate our quotation. Our engineers reply within one working day.

  • Cross-section (8 AWG or another size) and quantity in ft or m
  • Colour: black, white, red, green or another standard colour
  • Application: branch circuit, feeder, panelboard or control wiring
  • Termination temperature rating, if the circuit is being engineered
  • Destination market (US, Canada or other) and sample request, if needed

Your information is used for quotation only. No spam.

Inquiry received

Thanks — our engineers will reply within one working day.